Configuring a downlink policy, Configuring the customer-side port – H3C Technologies H3C S7500E Series Switches User Manual
Page 291
21-8
To do...
Use the command...
Remarks
Create a QoS policy and enter
QoS policy view
qos policy
policy-name
Required
Associate the class with the
behavior to map the CVLAN to the
SVLAN
classifier
tcl-name behavior behavior-name
Required
Repeat these steps to
create other
CVLAN-to-SVLAN
mappings.
Configuring a downlink policy
Follow these steps to configure a downlink policy to map SVLANs back to CVLANs:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Create a class and enter class
view
traffic classifier
tcl-name [ operator { and |
or
} ]
Configure an SVLAN as the match
criterion
if-match service-vlan-id vlan-id
Return to system view
quit
Required
Repeat these steps to
configure one class
for each SVLAN.
Create a traffic behavior and enter
traffic behavior view
traffic behavior behavior-name
Configure a CVLAN marking
action
remark customer-vlan-id vlan-id
Return to system view
quit
Required
Repeat these steps to
configure a behavior
for each CVLAN.
Create a QoS policy and enter
QoS policy view
qos policy
policy-name
Required
Associate the class with the
behavior to map the SVLAN to the
CVLAN
classifier
tcl-name behavior behavior-name
Required
Repeat these steps to
create other
CVLAN-to-SVLAN
mappings.
Configuring the customer-side port
Follow these steps to configure the customer-side port:
To do...
Use the command...
Remarks
Enter system view
system-view
—