6-6
To do...
Use the command...
Remarks
Enable the error frame seconds
summary alarm function
alarm oam
error-frame-seconds-summary
enable
Optional
The system generates an error
frame seconds summary alarm
when the number of error frame
seconds (in an error frame second,
at least one error frame occurs) in
a specific time period (for example,
1 minute) exceeds the
corresponding predefined
threshold.
By default, this function is enabled.
Configure the window size and
threshold for error frame seconds
summary alarms
alarm oam
error-frame-seconds-summary
{ window window | threshold
threshold
} *
Optional
By default, the window size is 600
(in unit of 100 ms), and the alarm
threshold is 1 second.
Enable the error symbol period
alarm function
alarm oam error-symbol-period
enable
Optional
The system generates an error
symbol period alarm when the
number of error frames in a
specific period (that is, the window
size) exceeds the corresponding
predefined threshold.
By default, this function is enabled.