beautypg.com

Testing the link between an onu and the olt, Testing the cable connected to an uni port – H3C Technologies H3C S7500E Series Switches User Manual

Page 68

background image

4-15

To do...

Use the command...

Remarks

Enable traffic encryption

encrypt enable

Optional

By default, data encryption is

enabled for downlink data.

Configure an encryption key

encrypt key key-value

Optional

If no encryption key is configured,

the system uses the default

encryption key.

Currently, the encrypt key

command is not supported.

Testing the Link Between an ONU and the OLT

Follow these steps to test the optical link between an ONU and the OLT:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter ONU port view

interface

onu interface-number

Test the optical link between the

ONU and the OLT

linktest

[ frame-number value |

frame-size value

| delay { on |

off

} | vlan-tag { on [ vlan-priority

value

| vlan-id value ] | off } ] *

Required

The following lists the default

values of the link test parameters.

Number of test frames: 20

Frame size: 1000 bytes

VLAN tag: not carried in testing

frames

Delay testing state: Off

The link connectivity between an ONU and the OLT can be tested only when the ONU is online.

Testing the Cable Connected to an UNI Port

Perform this operation to test the cable connected to the specified UNI port of the ONU once and to

display the testing result.

Follow these steps to test the cable connected to an UNI port: