beautypg.com

H3C Technologies H3C S7500E Series Switches User Manual

Page 307

background image

21-24

[SwitchC-behavior-b2] traffic behavior b3

[SwitchC-behavior-b3] remark service-vlan-id 503

[SwitchC-behavior-b3] quit

[SwitchC] qos policy p1

[SwitchC-policy-p1] classifier c1 behavior b1 mode dot1q-tag-manipulation

[SwitchC-policy-p1] classifier c2 behavior b2 mode dot1q-tag-manipulation

[SwitchC-policy-p1] classifier c3 behavior b3 mode dot1q-tag-manipulation

[SwitchC-policy-p1] quit

[SwitchC] qos policy p2

[SwitchC-policy-p2] classifier c4 behavior b1 mode dot1q-tag-manipulation

[SwitchC-policy-p2] classifier c5 behavior b2 mode dot1q-tag-manipulation

[SwitchC-policy-p2] classifier c6 behavior b3 mode dot1q-tag-manipulation

[SwitchC-policy-p2] quit

# Assign customer-side port Gigabitethernet 2/0/1 to CVLANs 101, 201, 301, 102, 202, 302, and
SVLANs 501 to 503. On this port, also enable customer-side QinQ, and apply uplink policy p1 to the
incoming traffic.

[SwitchC] interface gigabitethernet 2/0/1

[SwitchC-GigabitEthernet2/0/1] port link-type trunk

[SwitchC-GigabitEthernet2/0/1] port trunk permit vlan 101 201 301 102 202 302 501 502 503

[SwitchC-GigabitEthernet2/0/1] qinq enable downlink

[SwitchC-GigabitEthernet2/0/1] qos apply policy p1 inbound

[SwitchC-GigabitEthernet2/0/1] quit

# Assign customer-side port Gigabitethernet 2/0/2 to CVLANs 103, 203, 303, 104, 204, 304, and
SVLANs 501 to 503. On this port, also enable customer-side QinQ, and apply uplink policy p2 to the
incoming traffic.

[SwitchC] interface gigabitethernet 2/0/2

[SwitchC-GigabitEthernet2/0/2] port link-type trunk

[SwitchC-GigabitEthernet2/0/2] port trunk permit vlan 103 203 303 104 204 304 501 502 503

[SwitchC-GigabitEthernet2/0/2] qinq enable downlink

[SwitchC-GigabitEthernet2/0/2] qos apply policy p2 inbound

[SwitchC-GigabitEthernet2/0/2] quit

# Assign network-side Gigabitethernet 2/0/3 to SVLANs 501 to 503, set the port as a DHCP and ARP
trusted port, and enable network-side QinQ.

[SwitchC] interface gigabitethernet 2/0/3

[SwitchC-GigabitEthernet2/0/3] port link-type trunk

[SwitchC-GigabitEthernet2/0/3] port trunk permit vlan 501 502 503

[SwitchC-GigabitEthernet2/0/3] dhcp-snooping trust

[SwitchC-GigabitEthernet2/0/3] arp detection trust

[SwitchC-GigabitEthernet2/0/3] qinq enable uplink

4) Configuring

Switch

D

# Enable DHCP snooping.

system-view

[SwitchD] dhcp-snooping

# Assign port Gigabitethernet 2/0/1 to SVLANs 501 to 503.

[SwitchD] interface gigabitethernet 2/0/1

[SwitchD-GigabitEthernet2/0/1] port link-type trunk

[SwitchD-GigabitEthernet2/0/1] port trunk permit vlan 501 502 503