beautypg.com

H3C Technologies H3C S7500E Series Switches User Manual

Page 95

background image

6-10

To do...

Use the command...

Remarks

Configure the threshold of LLID

mismatch frame alarms

alarm llid-mismatch threshold

threshold

Optional

5000 frames by default

Enable the local stable alarm

function

alarm local-stable enable

Optional

The system generates a local

stable alarm when an ONU misuse

occurs in the system, for example,

when an OAM 2.0 ONU and an

OAM 3.3 ONU are mixed in the

same system. (All ONUs in the

same system must adopt the same

OAM version). A local stable alarm

is generated by the OLT side.

By default, this function is enabled.

Enable the critical event alarm
function

alarm oam critical-event enable

Optional
The system generates a critical
event alarm when one of the
following critical events occurs:
local link fault and dying gasp.

Enable the dying gasp alarm
function

alarm oam dying-gasp enable

Optional
The system generates a dying
gasp alarm when a system error, a
data loading error or any other
nonreversible error occurs.

Enable the error frame period
alarm function

alarm oam error-frame-period
enable

Optional
The system generates an error
frame period alarm when the
number of error frames in a
specific period (that is, the window
size) exceeds the corresponding
predefined threshold.
By default, this function is enabled.

Configure the window size and

threshold for error frame period

alarms

alarm oam error-frame-period

{ window window | threshold

threshold

} *

Optional

When the alarm threshold is set to

0, a lot of alarms are generated

immediately. Since alarm events

are carried in the OAM packets, a

lot of OAM packets are generated.

In this case, OAM packets may be

lost.

By default, the window size is 1

second, and the alarm threshold is

20 frames.