beautypg.com

Configuring global alarms – H3C Technologies H3C S7500E Series Switches User Manual

Page 87

background image

6-2

To do...

Use the command...

Remarks

Enable the statistics

sampling function

sample enable

Optional

Enabled by default

Configure the

statistics sampling

function

Configure the statistics

sampling interval

timer sample seconds

Optional

4 seconds by default

Enable alarm monitoring

function for the system

monitor enable

Optional

Enabled by default

Configure the

alarm monitoring

function

Configure the alarm

monitor period

timer monitor seconds

Optional

80 seconds by default

Configuring Global Alarms

Follow these steps to configure global alarms:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter FTTH view

ftth

Enable the software error alarm
function

alarm software-error enable

Optional
The system generates a software
error alarm when a signal error,
Data Access (DA) error, or
memory allocation failure occurs.
By default, this function is enabled.

Enable the bit error rate alarm
function

alarm bit-error-rate enable

Optional
When the total number of error bits
or bit error rate of the data
transferred between the OLT and
ONUs exceeds the alarm
threshold, a bit error rate alarm
occurs.
By default, this function is enabled.

Configure the monitor direction

and threshold for bit error rate

alarms

alarm bit-error-rate

{ direction

{ uplink | downlink |

up-down-link

} | threshold

threshold

}*

Optional

By default, the monitor direction is

up-down-link

, and the alarm

threshold of bit error rate is 10 (the

unit is 10

-9

).