Configuring an uplink policy for the, Customer-side port, Network-side port – H3C Technologies H3C S7500E Series Switches User Manual
Page 299
21-16
Task
Description
Configuring a downlink policy for the
Replaces local SVLANs and CVLANs with foreign SVLANs and
CVLANs (required).
Configuring the customer-side port
Configures VLAN and other settings required for two-to-two VLAN
mapping (required).
Configuring the network-side port
Configures VLAN and other settings required for two-to-two VLAN
mapping (required).
Configuring an uplink policy for the customer-side port
The uplink policy on the customer-side port modifies the SVLAN ID of incoming traffic.
Follow these steps to configure an uplink policy for the customer-side port:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Create a class and enter class view
traffic classifier
tcl-name [ operator
and
]
Specify a foreign CVLAN as a match
criterion
if-match customer-vlan-id vlan-id
Specify a foreign SVLAN as a match
criterion
if-match service-vlan-id
vlan-id
Return to system view
quit
Required
Repeat these steps to
create one class for each
foreign CVLAN and
SVLAN pair.
Create a traffic behavior and enter
traffic behavior view
traffic behavior
behavior-name
Configure an SVLAN marking action to
replace the foreign SVLAN ID with a
local SVLAN ID
remark service-vlan-id vlan-id
Return to system view
quit
Required
Repeat these steps to
configure one SVLAN
marking action for each
CVLAN and SVLAN pair.
Create a QoS policy and enter QoS
policy view
qos policy
policy-name
Required
Associate the class with the behavior
classifier
tcl-name behavior
behavior-name
Required
Repeat this step to create
other class-behavior
associations.
Configuring an uplink policy for the network-side port
The uplink policy on the network-side port modifies the CVLAN ID of incoming traffic.
Follow these steps to configure an uplink policy for the network-side port: