Configuring a downlink policy for the, Customer-side port – H3C Technologies H3C S7500E Series Switches User Manual
Page 300
21-17
To do...
Use the command...
Remarks
Enter system view
system-view
—
Create a class and enter class view
traffic classifier
tcl-name [ operator
and
]
Specify a foreign CVLAN as a match
criterion
if-match customer-vlan-id vlan-id
Specify a local SVLAN as a match
criterion
if-match service-vlan-id
vlan-id
Return to system view
quit
Required
Repeat these steps to
create one class for each
local SVLAN and foreign
CVLAN pair.
Create a traffic behavior and enter
traffic behavior view
traffic behavior
behavior-name
Configure a CVLAN marking action to
replace the foreign CVLAN ID with a
local CVLAN ID
remark
customer-vlan-id vlan-id
Return to system view
quit
Required
Repeat these steps to
configure one CVLAN
marking action for each
local SVLAN and foreign
CVLAN pair.
Create a QoS policy and enter QoS
policy view
qos policy
policy-name
Required
Associate the class with the behavior
classifier
tcl-name behavior
behavior-name
Required
Repeat this step to create
other class-behavior
associations.
Configuring a downlink policy for the customer-side port
The downlink policy on the customer-side port replaces local SVLAN and CVLAN pairs with foreign
SVLAN and CVLAN pairs.
Follow these steps to configure a downlink policy for the customer-side port:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Create a class and enter class view
traffic classifier
tcl-name [ operator
and
]
Specify a local CVLAN as a match
criterion
if-match customer-vlan-id vlan-id
Specify a local SVLAN as a match
criterion
if-match service-vlan-id
vlan-id
Return to system view
quit
Required
Repeat these steps to
create one class for each
local CVLAN and SVLAN
pair.