Configuring the customer-side port – H3C Technologies H3C S7500E Series Switches User Manual
Page 301
21-18
To do...
Use the command...
Remarks
Create a traffic behavior and enter
traffic behavior view
traffic behavior
behavior-name
Configure a CVLAN marking action to
replace the local CVLAN ID with a
foreign CVLAN ID
remark customer-vlan-id
vlan-id
Configure an SVLAN marking action to
replace the local SVLAN ID with a
foreign SVLAN ID
remark service-vlan-id vlan-id
Return to system view
quit
Required
Repeat these steps to
create one VLAN marking
behavior for each local
CVLAN and SVLAN pair.
Create a QoS policy and enter QoS
policy view
qos policy
policy-name
Required
Associate the class with the behavior
classifier
tcl-name behavior
behavior-name
Required
Repeat this step to create
other class-behavior
associations.
Configuring the customer-side port
Follow these steps to configure the customer-side port:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enter Ethernet interface view
interface interface-type
interface-number
—
Configure the port as a trunk port
port link-type
trunk
Required
The default link type of an
Ethernet port is access.
Assign the port to the local SVLANs
port trunk permit vlan
{ vlan-id-list | all }
Required
By default, a trunk port is in
only VLAN 1.
Apply the uplink policy configured for the
customer-side port to the incoming traffic
qos apply policy policy-name
inbound
Required
Apply the downlink policy configured for
the customer-side port to the outgoing
traffic
qos apply policy policy-name
outbound
Required