Fuel Point
Page 90 MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007
1
ICR error message display time: The length of time, in seconds, that an island card reader
will display messages from the Fuel Point reader. The default is 10.
2
Show miles-hours per gallon calculations: Should the miles-per-gallon (or hours-per-gallon)
be calculated and printed on the customer's receipt? The default is Yes. Cannot be use with
parameter 7.
3
Use meter #2 for calculations: Should meter 2 be used for per-gallon calculations? Meter 1
tracks miles-per-gallon; meter 2 tracks hours-per-gallon. The default is No (use meter 1).
4
VM field stored in auxiliary entry: Which vehicle module field should be stored in auxiliary
entry (see the following table for a list of available fields). The default is None.
5
VM field stored in router variable 1: Which vehicle module field should be stored in router
variable 1 (see the following table for a list of available fields). The default is None. Cannot be
use with parameter 7.
6
VM field stored in router variable 2: Which vehicle module field should be stored in router
variable 2 (see the following table for a list of available fields)? The default is None. Cannot
be use with parameter 7.
7
VM field stored in router variable as string: Which vehicle module field should be stored in
router variable as string? This router variable is the only one that can take alpha characters
along with numeric. Also, this parameter takes the complete 10 byte router allotment and
therefore, cannot be used with parameters 2, 5, or 6. The default is None.
Note: For alphanumeric fields, add 128 to the field number.
8
Default prompt for ICR entry #1 []: If the VM has not been encoded with any of the 3
optional entry requests, enter the request in this parameter. The ICR will provide the data that
would have been gathered by the VM. Possible prompts would be employee number or job
number of merchandise being transported. This field can hold up to 20 characters.
9
Default prompt for ICR entry #2 []: If the VM has not been encoded with any of the 3
optional entry requests, enter the request in this parameter. The ICR will provide the data that
would have been gathered by the VM. Possible prompts would be employee number or job
number of merchandise being transported. This field can hold up to 20 characters.
10
Default prompt for ICR entry #3 []: If the VM has not been encoded with any of the 3
optional entry requests, enter the request in this parameter. The ICR will provide the data that
would have been gathered by the VM. Possible prompts would be employee number or job
number of merchandise being transported. This field can hold up to 20 characters.
11
- 15. Card Data Field Layout, Offset, Width: The card data can contain up to 19 digits in up
to five (11 through 15) fields.
Note: Network interfaces may write over the VM field data stored as router variable 1 and/or
router variable 2 (parameters 5-7).
Select fields for inclusion from the following list by entering the field's number. Once you
enter the number, you will be prompted for the offset of that field into the card's data.