Command Permission Levels
6 – Command Permission Levels
Permission levels are from 0 to 10. CFN III commands are assigned permission levels that
restrict access to only those users who have an equal or greater permission level. Use the
configuration command PERM to assign permission levels to commands with the permission
configuration menu. The permission level of users is assigned with the Site Controller
command ADD SIGNON.
A few commands have fixed permission levels. The commands CALL, CLOSE, DISABLE
DUMP, DISABLE RAW, ECHO, ENABLE DUMP, ENABLE RAW, EXIT, HELP, LOG
MESSAGE, PAUSE, PORT, PRINT RECEIPT, and SET_VAR are always level 0.
A plain command can be assigned a different permission level than that same command with
the I or A option.
The table below shows the default permission levels for the Base commands and for the same
commands with an I or A option.
No.
Base
I/A Option
Command
1.
8
8
activate pump
2.
9
add allocation
3.
4
add inventory
4.
4
add drawer
5.
10
add signon
6.
4
add tank
7.
4
chdir
8.
2
check card
9.
2
2
deactivate pump
10.
4
disable gate
11.
9
disable history
12.
4
disable console
13.
4
disable PCU
14.
9
disable product
15.
4
8
disable pump
16.
4
disable reader
17.
4
4
enable gate
18.
4
10
enable history
19.
4
4
enable console
20.
4
4
enable PCU
21.
9
enable product
22.
4
8
enable pump
23.
4
4
enable reader
24.
10
10
fix transaction
25.
9
format