13 - fuel point, Global parameters, 13 – fuel point – Gasboy CFN III Config Mnl V3.4 User Manual
Page 95
MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007
Page 89
Fuel Point
13 – Fuel Point
Use the disk-based configuration program FUELPT to configure your Fuel Point system.
The FUELPT program has two sets of parameters: global and individual. From the main
FUELPT menu, press 1 for the global parameter submenu or press 2 for the individual
parameter submenu.
You must specify what type of device is being controlled by each ring. Possibilities are normal
pumps, gates and PCU pumps acting as if they are a gate. If opening a gate controlled by a gate
controller, the site will check the card created from the VM against lockout (if configured for
lockout with fuel point) and open the gate if the card is not locked out. A log message will be
generated, no transaction.
For pumps behaving like gates, when activated by the FPR, the pulse rate will be set to 1/G
and the pump will be activated for one gallon. The transaction error code will be set to “Gate”.
If the price/gallon is set to $.001, the site will convert the dollar total to zero at completion. It
should be noted that pumps acting like gates should be prevented from being activated by
ICRs/ Consoles if possible. Therefore you should configure such pumps to be on a different
cluster than real pumps.
Global Parameters
The default global parameters, in the order they are shown on the submenu, are displayed in
Figure 13-1: Default Global Parameters
***FPR Global Parameter ***
1. ICR error message display time: 10
2. Show miles-hour per gallon on receipt: yes
3. Use meter #2 for calculations: No
4. VM field stored in auxiliary entry: Odom/Hours 1
5. VM field stored in router variable 1: None
6. VM field stored in router variable 2: None
7. VM field stored in router variable as string: None
8. Default prompt for ICR entry #1:
9. Default prompt for ICR entry #2:
10. Default prompt for ICR entry #3:
Card Data Field Layout Offset Width
11. Card 0 6
12. Account 6 9
13. Vehicle 15 4
14. None
15. None
________________________________________________________________
Enter parameter number to modify or q to quit: