Gasboy CFN III Config Mnl V3.4 User Manual
Page 47

MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007
Page 41
Table Sizes
13
Price Table: The price table contains the prices for each price level under each price code.
This information is entered with the Site Controller command LOAD PRICE.
Each price takes one entry. Each price entry takes 10 bytes.
14
Limitation Table: The limitation table contains the limits under each limitation code. This
information is entered with the Site Controller command LOAD LIMITATION.
Each limit takes one entry. Each limit entry takes 10 bytes.
15
Authorization Table: The authorization table contains the product codes authorized under
each authorization code. This information is entered with the Site Controller command LOAD
AUTHORIZATION.
Each product code takes one entry. Each product code entry takes 6 bytes.
16
Broadcast Message Table: The broadcast message table holds the broadcast messages that
appear on the island card reader or gate controller when it is inactive. Broadcast messages are
programmed with the Site Controller command LOAD MESSAGE.
Each message takes one entry. Each message entry takes 38 bytes. The maximum number of
entries is 30.
17
Receipt Text Table: Used for receipt text sent from the network.
Each receipt entry takes 34 bytes. The minimum number of entries is 10, and the maximum
number of entries is 500.
Use the following guidelines to calculate the number of entries required:
• Each line of receipt text (up to 24 characters) sent by the network takes one entry.
• If the network uses the standard receipt (no custom receipt text), receipts do not require
any entries in this table.
• If the network inserts five lines of custom receipt text, it will use from five to seven entries
per receipt. (The exact number depends on how the network interface is set up).
• The Site Controller will keep a receipt for one day or 100 transactions after the transaction
is completed.
18
Receipt Heading Table: Holds the heading and footing lines that are printed on receipts.
Receipt heading and footing lines are programmed with the Site Controller command LOAD
HEADING.
Each heading line takes one entry. Each heading entry takes 46 bytes. The maximum number
of entries is 50.
19
Vehicle Table: Stores the vehicle numbers, odometer readings, and fuel information for the
MPG package.
Each vehicle in the MPG package takes one entry. Each entry takes 22 bytes.