How to change action permission levels, How to change pos parameters – Gasboy CFN III Config Mnl V3.4 User Manual
Page 87

MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007
Page 81
Console Configuration
How to Change Action Permission Levels
Use submenu 2 of the console configuration program to change the permission levels of Check
Point actions. (The table earlier in this chapter shows the default permission levels.) The
permissions defined here determine what permission level must be in effect to execute the
action.
The permission level in effect is the permission level of the operator who is signed on or the
permission level associated with the current setting of the manager keyswitch, whichever is
greater. The manager keyswitch permission levels are MANAGER=8, SUPERVISOR=4,
ON=1, and OFF=0. The operator permission levels are assigned with the Site Controller
command ADD SIGNON. There are 10 permission levels available, 0 through 9.
How to Change POS Parameters
For any changes after setup, use submenu 3 of the console configuration program to change
parameters for the Check Points/ Profit Points at a site. The following is a list of parameters
that can be changed.
Note: A leading asterisk (*) indicates Check Point only.
1
Allow postpay on POSs: Should postpay and prepay sales be allowed at the site, or should
only prepay sales be allowed? If only prepay sales are allowed, the Check Points/Profit Points
at the site will display * Must prepay * if a postpay sale is attempted.
2
POS printers: Which receipt printers are used by which Check Points or Profit Points at the
site? You can specify a receipt printer for consoles 1 through 4. Usually console 1 has receipt
printer 1, console 2 has receipt printer 2, and so on. If a console does not have a receipt printer,
enter the number of the printer where the receipt will be printed.
3
Safe-drop limit: What is the maximum amount of cash allowed in the cash drawer before the
safe-drop message is displayed? If there is no safe-drop limit, specify 0.
4
Tax rates, percent: Specify tax rates for taxes 1 through 8. Tax rates are specified in
hundredths of a percent. For example, a 7.8 percent tax is specified as 780, though it displays
as 7.80.
These taxes are assigned by number to products with the Site Controller command LOAD
PRODUCT.
Note: Tax rates and tax rounding boundaries (see the next item) are ignored if the tax tables
are loaded using the TAX program.
5
Tax rounding boundaries: How should the taxes specified in the parameter above be
rounded? Specify the upward rounding breakpoint in tenths of a cent (hundredths of a dollar).
For example, if taxes are to be rounded up at $.005 and down below $.005, enter a 5. (Also,
see the note under item 4, immediately above).