ICR Parameters
The ICR parameters determine what cluster each ICR is assigned to, and which pump is used
as a reference pump for transaction approval requests. From the READER main menu choose
submenu 3 to configure the ICR parameters.
You will be shown the following options, one by one:
1
Number of reader: Readers are assigned a number.
2
Cluster Number: Pumps and ICRs are assigned to clusters. A ICR can access only the pumps
that are assigned to the same cluster it is assigned to-unless it is assigned to cluster 0, in which
case it can access all clusters. Readers accessing chain pumps must be set to cluster 0.
3
Representative Pump Number: This is normally used to designate the pump number of the
dispenser reader, if a Tokheim DPT device or a Gilbarco CRIND device is used.
Another use: several pumps can be included in an ICR's cluster, and there can be a wide
difference between the maximum dollar or fill amounts authorized for each of those pumps;
therefore, when the verify-card step precedes the pump- select step, you can specify a
representative pump whose maximum dollar or fill amount will be the one used in requesting
verification for a card purchase. The price and limit for the reference pump are used to
calculate the dollar amount of the transaction authorization.
When there is just one pump in a cluster, that pump should be the representative pump.
4
Auto pump select: This is used for built-in dispenser readers, such as a Tokheim DPT or a
Gilbarco CRIND. This option is set to yes for a dispenser reader, or where the reader controls
only one pump. It causes the reader to not display the select pump step.
5
Device type: Designate the type of ICR you are configuring from these choices:
1
Gasboy island card reader
2
Epson stand-alone
3
Star RS-422 stand-alone
4
Star RS-232/Parallel stand-alone
5
Gasboy PAC reader
6
Tokheim DPT (2-line display)
7
Gilbarco CRIND device
8
Wayne CAT
9
Tokheim Insight or 4-line display DPT
The type of ICR selected sets the protocols used in communicating between that reader and the
Site Controller.
6
Printer number: If an ICR does not have a printer in its post, you may specify another ICR or
stand-alone printer to print that ICR's receipts. Similarly, if the reader assigned to a Profit
Point does not have a printer, you can use this parameter to assign a printer to that reader.