MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007

Page 61

Island Card Reader Configuration

ICR Parameters

The ICR parameters determine what cluster each ICR is assigned to, and which pump is used
as a reference pump for transaction approval requests. From the READER main menu choose
submenu 3 to configure the ICR parameters.

You will be shown the following options, one by one:

1

Number of reader: Readers are assigned a number.

2

Cluster Number: Pumps and ICRs are assigned to clusters. A ICR can access only the pumps
that are assigned to the same cluster it is assigned to-unless it is assigned to cluster 0, in which
case it can access all clusters. Readers accessing chain pumps must be set to cluster 0.

3

Representative Pump Number: This is normally used to designate the pump number of the
dispenser reader, if a Tokheim DPT device or a Gilbarco CRIND device is used.

Another use: several pumps can be included in an ICR's cluster, and there can be a wide
difference between the maximum dollar or fill amounts authorized for each of those pumps;
therefore, when the verify-card step precedes the pump- select step, you can specify a
representative pump whose maximum dollar or fill amount will be the one used in requesting
verification for a card purchase. The price and limit for the reference pump are used to
calculate the dollar amount of the transaction authorization.

When there is just one pump in a cluster, that pump should be the representative pump.

4

Auto pump select: This is used for built-in dispenser readers, such as a Tokheim DPT or a
Gilbarco CRIND. This option is set to yes for a dispenser reader, or where the reader controls
only one pump. It causes the reader to not display the select pump step.

5

Device type: Designate the type of ICR you are configuring from these choices:

1

Gasboy island card reader

2

Epson stand-alone

3

Star RS-422 stand-alone

4

Star RS-232/Parallel stand-alone

5

Gasboy PAC reader

6

Tokheim DPT (2-line display)

7

Gilbarco CRIND device

8

Wayne CAT

9

Tokheim Insight or 4-line display DPT

The type of ICR selected sets the protocols used in communicating between that reader and the
Site Controller.

6

Printer number: If an ICR does not have a printer in its post, you may specify another ICR or
stand-alone printer to print that ICR's receipts. Similarly, if the reader assigned to a Profit
Point does not have a printer, you can use this parameter to assign a printer to that reader.