2 alarm_property table – Comtech EF Data NetVue Release 1.1 User Guide User Manual
Page 212
Advanced Configuration (System Display)
Revision 3
NetVue User Guide
MN-NETVUE
10–75
Parameter name:
Field
Type
Null
Key
chParameter
text
Yes
Value in text format, as defined in the Element Protocol:
Field
Type
Null
Key
chDisplayValue
text
Yes
Example: For a discreet Parameter, if the value is 0, then chDisplayValue could contain False.
Date/time at which the Alarm was generated:
Field
Type
Null
Key
creationTime
datetime
Yes
10.9.2.2.2 alarm_property table
The general and custom Properties of the Elements in an Alarm state.
The ID of the original Alarm in the Alarm’s history tree:
Field
Type
Null
Key
AlarmId
bigint(20)
No
Primary
DataMiner ID:
Field
Type
Null
Key
DataMinerID
int(11)
No
Primary
Name of the Property:
Field
Type
Null
Key
Name
varchar(45)
No
Primary
A value from the slenumvalues table indicating the type of NetVue item to which the Property is linked:
Field
Type
Null
Key
Type
smallint(6)
No
Primary
•
44 (Element)
•
45 (Service)
•
46 (View)
•
49 (Alarm)