Page 121

Alerter
Revision 3
NetVue User Guide
MN-NETVUE
6–8
6.4.2 Set the Alarm Filter
You can set the Skyline Alerter to filter specified parameters. This filtering restricts alerts to a specific
subset of alarms.
Decide whether to use a simple client-side filter, an advanced client-side filter or a server-side filter. If you
use any client-side filter, all alarms are sent to the client. If you use a server-side filter, only the
unacknowledged alarms are sent to the client.
1. On the Skyline Alerter main window, click the Settings button (see Figure 6-6 Skyline Alerter
2. On the Options window, select the Filter tab.
Figure 6-13 Options window | Filter tab
3. If you use Client-side filtering, select the applicable options:
a) Simple Client-side filter – in the Clientside filter section,
i. Select which alarm types must cause alerts.
b) Advanced Client-side filter –
i. Select the Use clientside filter option.
ii. Click the ellipsis button on the right to open a list.
iii. Select one of the available client-side filters (as configured in System Display).