Select ean-8 bar code (dc4 dc4 esc ! nn 1 pp em) – Compuprint 4247-Z03 Programmer Manual User Manual
Page 83
Control
Hex
Name
DC4 DC4 ESC ! NN 6 PP EM
14 14 1B 21 06
Select UPC 2-Digit Bar Code
(Magazine)
DC4 DC4 ESC ! NN 7 PP EM
14 14 1B 21 07
Select UPC 5-Digit Bar Code
(Magazine)
DC4 DC4 ESC ! NN 17 PP EM
14 14 1B 21 11
Select 2 of 5 INTERLEAVED Bar Code
DC4 DC4 ESC ! NN 18 PP EM
14 14 1B 21 12
Select 2 of 5 INDUSTRIAL Bar Code
DC4 DC4 ESC ! NN 19 PP EM
14 14 1B 21 13
Select 2 of 5 MATRIX Bar Code
DC4 DC4 ESC ! NN 20 PP EM
14 14 1B 21 14
Select CODE 3 of 9 Bar Code
DC4 DC4 ESC ! NN 22 PP EM
14 14 1B 21 16
Select CODABAR Bar Code
DC4 DC4 ESC ! NN 23 PP EM
14 14 1B 21 17
Select CODE 128 Bar Code
DC4 DC4 ESC ! NN 24 PP EM
14 14 1B 21 18
Select POSTNET Bar Code
DC4 DC4 ESC ( GS {N1} {DATA1} {N2} {DATA2}
EM
14 14 1B 28 1D
DD..DD 1D DD..DD 19
Print Bar Code Selection
DC4 DC4 ESC @
14 14 1B 40
Reinitialize Printer
DC4 DC4 ESC 1 NN
14 14 1B 31
Set Vertical Spacing n/144 Inch
DC4 DC4 ESC 3 1
14 14 1B 33 31
Set Vertical Spacing to 12 Lines/30mm
DC4 DC4 ESC 3 3
14 14 1B 33 33
Set Vertical Spacing to 3 Lines/30mm
DC4 DC4 ESC 3 4
14 14 1B 33 34
Set Vertical Spacing to 4 Lines/30mm
DC4 DC4 ESC 3 6
14 14 1B 33 36
Set Vertical Spacing to 6 Lines/30mm
DC4 DC4 ESC 3 8
14 14 1B 33 38
Set Vertical Spacing to 8 Lines/30mm
DC4 DC4 ESC 5
14 14 1B 35
Eject Single Sheet or Form Feed
DC4 DC4 ESC A
14 14 1B 41
Set 15, 17.1, or 20 CPI
DC4 DC4 ESC N
14 14 1B 4E
Load or Park Fanfold from a Rear Path
DC4 DC4 ESC T
14 14 1B 54
Load or Park Fanfold from a Front Path
DC4 DC4 ESC Y
14 14 1B 59
Select Emulation
DC4 DC4 ESC Z
14 14 1B 5A
Select AFTA in Column
DC4 DC4 ESC g
14 14 1B 67
Select Resident Font
DC4 DC4 ESC h
14 14 1B 68
Request to Read Configuration
DC4 DC4 ESC h
14 14 1B 68 .....
Printer Configuration Response
DC4 DC4 ESC i
14 14 1B 69 .....
Write Configuration Response
DC4 DC4 ESC i
14 14 1B 69
Write Configuration Acknowledgement
DC4 DC4 ESC p
14 14 1B 70
Select Print Quality
Select EAN-8 Bar Code (DC4 DC4 ESC ! NN 1 PP EM)
14
14
1B
21
NN
01
PP
19
This control selects the EAN-8 bar code.
The DATA field must contain only ASCII numeric (0 to 9) data, and must be eight bytes long, check digit
included.
Chapter 2. Epson FX-1050 Data Stream
63