Explanation: The unit/module width specified in the
Write Bar Code Data Descriptor field is not supported.

Alternate Exception Action: Use closest smaller
width supported or the device default for those devices
with only one fixed default value.

X'040700'

Element Height Specified Is Not
Supported

Explanation: The element height specified in the Write
Bar Code Data Descriptor field is not supported.

Alternate Exception Action: Use closest height
supported.

X'040800'

Height Multiplier Specified Is Not
Supported

Explanation: The height multiplier specified in the
Write Bar Code Data Descriptor field is not supported.

Alternate Exception Action: Use closest multiplier
supported.

X'040900'

Wide/Narrow Ratio Is Not Supported

Explanation: The wide/narrow ratio specified in the
Write Bar Code Data Descriptor field is not supported.

Alternate Exception Action: Use the printer default
wide element width. The default wide element width and
the specified or default unit/module width should be
such that a wide/narrow ratio of 2.50 or 3.00 results.

X'040A00'

Invalid Symbol Reference Point

Explanation: The symbol reference point given in the
Write Bar Code command is not a valid or supported
value.

Alternate Exception Action: None.

X'040B00'

Invalid Bar Code Modifier

Explanation: The bar code modifier, byte 17 of the
Bar Code Data Descriptor structured field, is not a valid
or supported value for the bar code type specified by
byte 16 of the same structured field.

Alternate Exception Action: None.

X'040C00'

Invalid Bar Code Data Length

Explanation: The length of the variable data (as given
in bytes 5-n of the Write Bar Code command) to be
bar-encoded/printed, plus any printer-generated check
digits to be coded/printed, is not a valid or supported
value.

Alternate Exception Action: None.

X'040E00'

Check Digit Calculation Error

Explanation: A first check digit calculation resulting in
a value of 10 is defined as an error in various of the
modifier options (byte 17 of the Bar Code Data
Descriptor structured field) for the MSI bar code.

Alternate Exception Action: None.

X'041000'

HRI Location Not Supported

Explanation: HRI location specified in the FLAGS byte
of the WBC command is not a supported location.

Alternate Exception Action: None.

X'041100'

Attempt to Print Portion of Symbol
Outside Block or VPA

Explanation:

1. A portion of the bar code presentation space, as

mapped into the block, extends outside the bar code
block boundaries, or a portion of the bar code block
extends outside of the logical page (or current
overlay).

2. An attempt is made to print a bar code symbol or

HRI outside the physical page.

3. The symbol reference point lies outside the bar code

block, presentation space, or logical page (or current
overlay).

Alternate Exception Action: None.

Chapter 5. IPDS Exception Reporting Codes

201