Parameter values, Command format – Compuprint 4247-Z03 Programmer Manual User Manual
Page 120
2. The printer default font is Gothic for DP and fast draft print quality and Courier for DP Text and NLQ
print quality. To determine the current values for CPI, language and quality, refer to the User’s Guide
for your printer.
3. When Local Font ID equals FF is used, the latest inline sequence established in “Logical Page
Descriptor (LPD)” on page 111 determines whether to print in a left-to-right or right-to-left sequence.
The default when the printer is powered on is the left-to-right sequence.
Parameter Values
The 4247 Printer allows flexibility in selecting various options to perform a wide range of functions.
Parameter values are initially set at the factory. The printer uses these values to format the page and to
control forms movement. The parameter values also allow the operator to select the printer address,
language, and print mode and compatibility options, and to turn the alarm on or off.
The printer can use the initial factory set values, or the operator can change these values. Any new value
selection made at the operator panel becomes the new parameter value immediately upon selection. If this
configuration is saved by the operator into the power-on custom set, this value remains as the new
parameter value, even after the printer power switch is turned Off (O).
The operator can select the following parameter values at the operator panel and change them:
v
Characters per inch (CPI)
v
Lines per inch (LPI)
v
Maximum print position (MPP)
v
Maximum page length (MPL) (See Note)
v
Language
v
Print quality
v
Alarm (Enabled/Disabled)
v
Graphics and Bar Code mode
v
Left margin
v
Emulation mode
Note: An MPL setting that results in a page length less than 762 mm (3 in.) causes a throughput
reduction. A maximum reduction of about 50 percent occurs at an MPL setting of one line per page.
The application program can override any of the parameter values, except for turning the alarm on or off
changing the address selection, changing the emulation determines what parameter value the printer uses:
1. The printer uses the program specified value.
2. If no program command has specified the value, the printer uses the current parameter value.
Command Format
All the printer commands use the following format:
Length
Command
Flag
Correlation ID (Optional)
Data
The following chart shows the purpose of each field:
Byte
Field
Description
0-1
Length
Total Command Length, Including the Length Bytes
2-3
Command
Command Type
100
Programmer Manual