Compuprint 4247-Z03 Programmer Manual User Manual
Page 228
X'023F02'
Font Index Not Loaded
Explanation:
1. The font inline sequence in Load Font Equivalence
command is not supported or not supported with the
current Text Orientation.
2. The Font Index specified in a Load Font
Equivalence command called out by a Set Coded
Font Local text control is not loaded.
Alternate Exception Action: None.
X'024201'
WIC Pel Count < Minimum Required
Explanation: The Target or Source Pel Count value
on the Write Image Control command is less than 1.
Alternate Exception Action: None.
X'024301'
WIC Pel Count > Maximum Allowed
Explanation: The Target or Source Pel Count value
on the Write Image Control command is greater than
the valid or supported maximum.
Alternate Exception Action: None.
X'024401'
WIC Scan Count < Minimum Required
Explanation: The Target or Source Scan Count value
on the Write Image Control command is less than 1.
Alternate Exception Action: None.
X'024501'
WIC Scan Count > Maximum Allowed
Explanation: The Target or Source Scan Count value
on the Write Image Control command is greater than
the valid or supported maximum.
Alternate Exception Action: None.
X'024601'
Invalid WIC Source Image Format
Explanation:
1. The Compression Algorithm value (Byte 8) is not a
valid or supported value.
2. The (Pel) Data Format value (Byte 9) in the Write
Image Control command is not X'00'.
Alternate Exception Action: None.
X'024701'
Invalid WIC Scale Factor Value
Explanation:
1. The Pel Count Scale Factor value on the Write
Image Control command is not a valid or supported
value.
2. The Scan Count Scale Factor value on the Write
Image Control command does not equal the Pel
Count Scale Factor.
Alternate Exception Action: None.
X'024702'
Invalid LFE Font Inline Sequence
Explanation: The Font Inline Sequence parameter in
a Load Font Equivalence command is not a valid or
supported value.
Alternate Exception Action: None
X'024801'
Invalid WIC Scan Line Direction
Explanation: The Scan Line Direction parameter value
on the Write Image Control command is not a valid or
supported value.
Alternate Exception Action: None.
X'024802'
Invalid Font Section Number in LSS
command
Explanation: The section number specified in the LSS
command is not a valid or supported value.
Alternate Exception Action: None.
X'024901'
Invalid WIC Scan Sequence Direction
Explanation: The Scan Line Sequence Direction value
specified on the Write Image Control command is not
plus ninety degrees from the Scan Line Direction value.
Alternate Exception Action: None.
Note: Plus ninety from 270, (X'8700') must be X'0000'.
X'024902'
Invalid Starting Code Point in LSS
command
Explanation: The Starting Code Point in the LSS
command is not a valid or supported value.
Alternate Exception Action: None.
X'024A01'
Invalid WIC Coordinate Specification
Explanation:
1. The Coordinate Definition value on the Write Image
Control command is not a valid or supported value.
2. The First Pel Location (X or I Direction) value on the
Write Image Control command is not a valid or
supported value.
3. The First Pel Location (Y or B Direction) value on
the Write Image Control command is not a valid or
supported value.
Alternate Exception Action: None.
208
Programmer Manual