beautypg.com

Compuprint 4247-Z03 Programmer Manual User Manual

Page 228

background image

X'023F02'

Font Index Not Loaded

Explanation:

1. The font inline sequence in Load Font Equivalence

command is not supported or not supported with the
current Text Orientation.

2. The Font Index specified in a Load Font

Equivalence command called out by a Set Coded
Font Local text control is not loaded.

Alternate Exception Action: None.

X'024201'

WIC Pel Count < Minimum Required

Explanation: The Target or Source Pel Count value
on the Write Image Control command is less than 1.

Alternate Exception Action: None.

X'024301'

WIC Pel Count > Maximum Allowed

Explanation: The Target or Source Pel Count value
on the Write Image Control command is greater than
the valid or supported maximum.

Alternate Exception Action: None.

X'024401'

WIC Scan Count < Minimum Required

Explanation: The Target or Source Scan Count value
on the Write Image Control command is less than 1.

Alternate Exception Action: None.

X'024501'

WIC Scan Count > Maximum Allowed

Explanation: The Target or Source Scan Count value
on the Write Image Control command is greater than
the valid or supported maximum.

Alternate Exception Action: None.

X'024601'

Invalid WIC Source Image Format

Explanation:

1. The Compression Algorithm value (Byte 8) is not a

valid or supported value.

2. The (Pel) Data Format value (Byte 9) in the Write

Image Control command is not X'00'.

Alternate Exception Action: None.

X'024701'

Invalid WIC Scale Factor Value

Explanation:

1. The Pel Count Scale Factor value on the Write

Image Control command is not a valid or supported
value.

2. The Scan Count Scale Factor value on the Write

Image Control command does not equal the Pel
Count Scale Factor.

Alternate Exception Action: None.

X'024702'

Invalid LFE Font Inline Sequence

Explanation: The Font Inline Sequence parameter in
a Load Font Equivalence command is not a valid or
supported value.

Alternate Exception Action: None

X'024801'

Invalid WIC Scan Line Direction

Explanation: The Scan Line Direction parameter value
on the Write Image Control command is not a valid or
supported value.

Alternate Exception Action: None.

X'024802'

Invalid Font Section Number in LSS
command

Explanation: The section number specified in the LSS
command is not a valid or supported value.

Alternate Exception Action: None.

X'024901'

Invalid WIC Scan Sequence Direction

Explanation: The Scan Line Sequence Direction value
specified on the Write Image Control command is not
plus ninety degrees from the Scan Line Direction value.

Alternate Exception Action: None.

Note: Plus ninety from 270, (X'8700') must be X'0000'.

X'024902'

Invalid Starting Code Point in LSS
command

Explanation: The Starting Code Point in the LSS
command is not a valid or supported value.

Alternate Exception Action: None.

X'024A01'

Invalid WIC Coordinate Specification

Explanation:

1. The Coordinate Definition value on the Write Image

Control command is not a valid or supported value.

2. The First Pel Location (X or I Direction) value on the

Write Image Control command is not a valid or
supported value.

3. The First Pel Location (Y or B Direction) value on

the Write Image Control command is not a valid or
supported value.

Alternate Exception Action: None.