beautypg.com

Absolute move inline (ami), Absolute move baseline (amb), Relative move inline (rmi) – Compuprint 4247-Z03 Programmer Manual User Manual

Page 156: Relative move baseline (rmb)

background image

Description: This control specifies a distance, which the printer adds to the current baseline coordinate
when the printer performs a Begin Line control.

Parameters P1P2 form a two byte value that specifies the baseline increment in units. All values between
X'8000' and X'7FFF' are valid. A value of X'FFFF' causes the printer to use the value in the LPD
command.

Absolute Move Inline (AMI)

2BD3

04

C6 (C7)

P1P2

Description: This control moves the inline coordinate in the I direction. The move is to an absolute
position on the inline (I) axis.

Parameters P1P2 form a two byte value that specifies the new inline coordinate in units. All values
between 0 and X'7FFF' are valid.

Notes:

1. Values as large as X'7FFF' are valid but might be off the page.

2. Several Absolute Move Inline controls used in a single line reduce throughput. If possible, replace

Absolute Move Inline controls with spaces, or combine multiple Absolute Move Inline controls into a
single Absolute Move Inline control.

Absolute Move Baseline (AMB)

2BD3

04

D2 (D3)

P1P2

Description: This control moves the baseline coordinate in the B direction. The move is to an absolute
position on the baseline (B) axis.

Parameters P1P2 form a two byte value that specifies the new baseline coordinate in units. All values
between 0 and X'7FFF' are valid.

Note: Baseline coordinate values that require a negative baseline displacement in order to print results in

an error if the LPD command specifies ordered printing.

Relative Move Inline (RMI)

2BD3

04

C8 (C9)

P1P2

Description: This control moves the inline coordinate relative to the current line coordinate position.

Parameters P1P2 form a two byte value that specifies the displacement value in units. All values between
X'8000' and X'FFFF' are valid. Negative values are in twos-complement form.

Notes:

1. Values as large as X'FFFF' are valid but might be off the page.

2. Several Relative Move Inline controls used in a single line reduce throughput. If possible, replace

Relative Move Inline controls with spaces, or combine multiple Relative Move Inline controls into a
single Relative Move Inline control.

Relative Move Baseline (RMB)

2BD3

04

D4 (D5)

P1P2

136

Programmer Manual

This manual is related to the following products: