beautypg.com

Compuprint 4247-Z03 Programmer Manual User Manual

Page 225

background image

command is not a valid or supported value.

Alternate Exception Action: None.

X'020501'

Invalid Spanning Sequence

Explanation: A Write Text or Write Graphics command
is required to complete a partial order, control, or
double-byte character code and another command was
received other than an XOA command.

Alternate Exception Action: None.

X'020502'

Unsupported Baseline Move

Explanation: Unsupported advancement of the
baseline coordinate toward the I-axis.

Alternate Exception Action: None.

X'020505'

Structured Field Unit-Base Invalid

Explanation: The unit-base (measurement units)
specified in the Output Control or the Data Descriptor
structured field of the WGC or WBCC command is not a
valid or supported value.

Alternate Exception Action: None.

X'020601'

Begin Suppression Error

Explanation: Begin Suppression encountered in the
same unit (page, segment or overlay) before previous
suppression in that unit ended.

Alternate Exception Action: None.

X'020605'

Structured Field Units Invalid

Explanation:

1. The units specified in the Output Control or the Data

Descriptor structured field of the WGC or WBCC
command is not a valid or supported value.

2. The result of the calculation cannot be represented

in the printer. This may result from the WGC GDD
window limits being very close together.

3. Coordinate overflow while scaling graphics. Possible

if scaling coordinates require multiplication by a
value greater than 1.

Alternate Exception Action: None.

X'020705'

Structured Field Extents Not Supported

Explanation: The extents specified in the Output
Control or Data Descriptor structured field of the WGC
or WBCC command are not a valid or supported value.

The window values of the WGC GDD structured field
are not consistent; therefore, the value of XL is larger
than the value of XR or the value of YB is larger than
the value of YT.

Alternate Exception Action: None.

X'020805'

Invalid Mapping Option

Explanation: A mapping option specified in the Output
Control structured field of the WGC or WBCC command
is not a valid or supported value.

Alternate Exception Action: None.

X'020905'

Invalid Axis Offsets

Explanation: The axis offsets specified in the Output
Control structured field of the WGC or WBCC command
are not valid or supported values.

Alternate Exception Action: None.

X'020B05'

Invalid Structured Field Identifier

Explanation: A two-byte structured field identifier in a
WGC or WBCC command is invalid or out of sequence.

Alternate Exception Action: None.

X'020F01'

Invalid Text Orientation

Explanation: Baseline or Inline orientation specified in
Set Text Orientation is not a valid or supported value.

Alternate Exception Action: Use an inline orientation
of 0 degrees and a baseline orientation of 90 degrees.

X'021001'

Invalid Margin

Explanation: The margin position is not a valid or
supported value.

Alternate Exception Action: None.

X'021101'

Invalid Baseline Increment

Explanation: The value of the baseline increment is
not a valid or supported value.

Alternate Exception Action: None.

X'021201'

Invalid Intercharacter Adjustment

Explanation:

1. The value of the intercharacter adjustment is not a

valid or supported value.

2. The intercharacter adjustment direction is not a valid

or supported value.

Alternate Exception Action:

1. Ignore the control sequence and continue

presentation with the parameter values according to
the hierarchy (the hierarchy is the last valid value
received or if none received then use the LPD
value).

2. Use direction = zero.

Chapter 5. IPDS Exception Reporting Codes

205

This manual is related to the following products: