beautypg.com

AMETEK CTS 3.0 User Manual

Page 143

background image

User Manual

Compliance Test System 3.0

139

Measurement

Specification

Unit

Power

Range PACS-1 / PACS-3

0.1 - 12,500

W/ph

Range PACS-3-75

0.1 - 22,500

W/ph

Accuracy

± 0.25 % ± 0.25 % FS ± 20mW

mW

Resolution

0.1

W

Apparent Power

Range PACS-1 / PACS-3

0.01 - 12,500

VA/ph

Range PACS-3-75

0.01 - 22,500

VA/ph

Accuracy

± 0.15% ± 0.15% FS ± 20

mVA

Resolution

0.01

VA

Power Factor

Range

0.00 - ± 1.00

Accuracy

± 0.05

Resolution

0.01

Crest Factor

Range

20:1

Accuracy

± 0.005

Resolution

0.001

Frequency

Range

45 - 65

Hz

Accuracy

0.1 % of reading

Hz

Resolution

0.1

Hz

Harmonic Analysis

Range

Fundamental to 40

th

Accuracy Fundamental

±0.05% FS±0.05%/kHz

Accuracy Harmonics

±0.1 %±0.1%/kHz

Measurement window

10, 12 or 16 periods

Smoothing filter

1.5

sec

Flicker

Pst

Range

0.1 - 10

Pst

Accuracy

3

%

Resolution

0.01

Integration time

10

min

Plt

Range

0.1 - 10

d

max

Range

0 - 100

%

d

c

Range

0.1 - 100

%

d

t

Range

0.1 - 100

%

d

t

over3%(4%)

Range

0 - 1000

ms