15. Specifications

15.1

About This Chapter

This chapters provides the technical specifications of the CTS measurement system and the Power
Analysis and Conditioning System unit (PACS-1. PACS-3 and PACS-3-75). If the CTS system you
have includes an AC power source, refer to the separate AC source user manual that shipped with
the AC source.

Note:

All specifications listed in the manual are valid at an ambient temperature of 23° ± 5° and
apply after a 15 minute warm-up period.

15.2

Measurement System Specifications

The CTS measurement system is implemented using a high speed Analog to Digital ISA plug in
board. This board needs to be installed properly in order to function according to the specification
listed here.

Measurement

Specification

Unit

Bandwidth

Anti Aliasing

> 60 dB at 5 KHz

Bandpass ripple

< 2 % up to 2.5 KHz

%

Volts

Range

0.01 - 312.00

V

rms

Max. input

1000

V

peak

Max. crest factor

5:1

Accuracy

± 0.1 % ± 0.05 % FS ± 3 mV

mV

Resolution

10

mV

Voltage CMRR

80

dB

RMS Current

Current ranges (Auto ranging)

4,16,40

A

rms

Current ranges (Auto ranging) -75

4,16,75

A

rms

Highest range PACS-1 / PACS-3

40.00

A

rms

Highest range PACS-3-75

75.00

A

rms

Max. input [permanent, no damage if
< 200 A

peak

] PACS-1 / PACS-3

40.00

A

rms

Max. input [permanent, no damage if
< 200 A

peak

] PACS-3-75

75.00

A

rms

Max. Crest Factor [High Range]

5:1

Max. Crest Factor [High Range] -75

2.5:1

Max. Crest Factor [Low Range]

20:1

Accuracy

± 0.1 % ± 0.05 % FS ± 3 mA

mA

Resolution

1

mA