beautypg.com

Sample file iec411.411 – AMETEK CTS 3.0 User Manual

Page 140

background image

Compliance Test System 3.0

User Manual

136

14.3

Sample File IEC411.411

The CIGUI32 program supports two different implementations of the IEC 61000-4-11 standard.
One is based on the -411 firmware option. This version does not use an ini file but stored test
sequences in a proprietary format instead. If your system uses an iX Series AC power source but
does not have the -411 option installed, the following IEC411.411 file is used to store the test
sequence. You can create additional files with the .411 extension and save them in the

C:\Program Files\California Instruments\Cigui32\IEC_Test directory.

Note that the CIGuiSII program only supports the

–411 option based tests.

Following is a listing of the default IEC411.411 file shipped with the CIGUI32 program. If for some
reason your 411 file is lost or you would like to restore it to its original condition, use the values
shown here.

[IEC-1000-4-11]
PreTest = 3
SeqRepeat = 3
SeqDuration = 10
InterSeqDelay = 1
UserPrompt = User
intervention required. Press
OK when ready to continue
SeqNumberDips = 21
MeasUpdateRate = 1000
CycleTime0 = 0.5
StartPhase0 = 0
TestLevel0 = 0
GapDelay0 = 2
CycleTime1 = 0.5
StartPhase1 = 180
TestLevel1 = 0
GapDelay1 = 2
CycleTime2 = 1
StartPhase2 = 0
TestLevel2 = 0
GapDelay2 = 5
CycleTime3 = 5
StartPhase3 = 0
TestLevel3 = 0
GapDelay3 = 2
CycleTime4 = 10
StartPhase4 = 0
TestLevel4 = 0
GapDelay4 = 2

CycleTime5 = 25
StartPhase5 = 0
TestLevel5 = 0
GapDelay5 = 2
CycleTime6 = 50
StartPhase6 = 0
TestLevel6 = 0
GapDelay6 = 2
CycleTime7 = 0.5
StartPhase7 = 0
TestLevel7 = 40
GapDelay7 = 2
CycleTime8 = 0.5
StartPhase8 = 180
TestLevel8 = 40
GapDelay8 = 2
CycleTime9 = 1
StartPhase9 = 0
TestLevel9 = 40
GapDelay9 = 2
CycleTime10 = 5
StartPhase10 = 0
TestLevel10 = 40
CycleTime11 = 10
StartPhase11 = 0
TestLevel11 = 40
CycleTime12 = 25
StartPhase12 = 0
TestLevel12 = 40
CycleTime13 = 50

StartPhase13 = 0
TestLevel13 = 40
CycleTime14 = 0.5
StartPhase14 = 0
TestLevel14 = 70
CycleTime15 = 0.5
StartPhase15 = 180
TestLevel15 = 70
CycleTime16 = 1
StartPhase16 = 0
TestLevel16 = 70
CycleTime17 = 5
StartPhase17 = 0
TestLevel17 = 70
CycleTime18 = 10
StartPhase18 = 0
TestLevel18 = 70
CycleTime19 = 25
StartPhase19 = 0
TestLevel19 = 70
CycleTime20 = 50
StartPhase20 = 0
TestLevel20 = 70

FallTimeVar = 2
HoldTimeVar = 1
RiseTimeVar = 2
VarLevel0 = 40
VarLevel1 = 0