About this chapter – AMETEK CTS 3.0 User Manual
Page 102
Compliance Test System 3.0
User Manual
98
8.
IEC 61000-4-13 Harmonics and Interharmonics Immunity Test
8.1
About this Chapter
The IEC413 option is capable of performing IEC 61000-4 section 13 Harmonics and inter
harmonics low frequency immunity tests. The tests are based on IEC 61000-4-13:2002-03, First
Edition. It is assumed that the user has a copy of the test standard available. This manual section
only cover operation of the
–413 option from the front-panel of the iX Series power source.
Note 1: The initial release of the
–413 option for the iX Series power sources was based on a
draft version (CDV) of the IEC 61000-4-13 standard. Minor changes were made between the CDV
draft and the final released version. Units with firmware revision 2.37 or higher conform to the
official released IEC standard. Units with older firmware conform to the draft version. A firmware
upgrade can be ordered through California Instruments‟ service department by contacting
and requesting part number CIC463. Provide the model and serial number
of the unit (master unit in multi-box systems) to ensure the correct firmware is provided. The
firmware revision is displayed on the LCD screen immediately after power up for a few seconds. It
can also be queried over the bus using the “*IDN?” command.
Where relevant, the requirement for the correct firmware revision to obtain specific test modes is
indicated in this manual.
Note 2: The
–413 option is only available on iX Series AC power sources, not i Series. It is
possible to upgrade most i Series AC source to an iX Series and add the
–413 option. Contact the
California Instruments service department for information.
Figure 8-1: IEC 61000-4-13 Test Window