13. IEC 61000-4-29p DC Dips and Interruptions Immunity Test

(Pre-compliance)

The IEC 61000-4-29 implementation in the CIGui32 or CIGuiSII is based on the IEC 61000-4-29
standard dated march 24, 2000. This test is offered as a pre-compliance level test only. Not
all the DC supply rise and fall time and maximum current requirements can be met under all
conditions. (See paragraph 13.8 for details.) Test parameters can be changed if needed using
the parameter data entry grid. Several generic test parameter files are distributed with the
CIGui32 or CIGuiSII program. These files can be edited as well. IEC 61000-4-29 Test setup
parameter files use a “.429” extension. More than one .429 file may reside in the IEC_Test
directory or any other directory. The operator may select the one to run from the File, Open dialog.

Figure 13-1: IEC 61000-4-29 Test Window