Figure 6-5. Connecting Third New Battery

8. Remove the last old battery and connect the dummy connector cap disconnected in Step

4. See the following figure.

Figure 6-6. Reconnecting Dummy Connector Cap

9. Replace the cover on the robot.

l

Tightening torque: IP-54/65 models - Hex socket bolt: 2.0 N·m (1.5 ft-lbf)

l

Tightening torque: Standard models - cross pan-head screw: 0.59 N·m (0.4 ft-lbf)

6.6 Replacing the MB-60R/eMB-60R Amplifier

NOTE: An eMB-60R has two Ethernet connectors; an MB-60R has none.