Chapter 4: System Installation

Adept Viper s650/s850 Robot with MB-60R/eMB-60R User’s Guide, Rev F

Page 56 of 100

WARNING: Appropriately-sized Branch Circuit Pro-
tection and Lockout / Tagout Capability must be pro-
vided in accordance with the National Electrical Code
and any local codes.

Specifications for AC Power

Table 4-5.  Specifications for 200/240 VAC User-Supplied Power Supply

Auto-Ranging
Nominal Volt-

age Ranges

Minimum

Operating

Voltage

1

Maximum
Operating

Voltage

Frequency/

Phasing

Recommended
External Circuit

Breaker, User-

Supplied

200 to 240 V

180 V

264 V

50/60 Hz

1-phase

10 Amps

1

Specifications are established at nominal line voltage. Low line voltage can affect robot per-

formance.

The Adept robot system is intended to be installed as a piece of equipment in a per-
manently-installed system.

Table 4-6. Typical Robot Power Consumption

1

Robot

Move

Average Power

(W)

Peak Power

(W)

2

Adept Viper s650

No load - Adept cycle

3

371

947

5.0 kg - Adept cycle

3

477

1526

5.0 kg - all joints move

834

2088

Adept Viper s850

No load - Adept cycle

3

358

1237

5.0 kg - Adept cycle

3

407

1202

5.0 kg - all joints move

704

2090

1

Typical power data is with 220 VAC, 60 Hz, 1-phase nominal input.

2

For short durations (100 ms).

3

Adept cycle: the robot tool per over, 25 mm down, and backforms continuous path,

straight-line motions 25 mm up, 305 mm along the same path. COARSE is enabled and
BREAKs are used at each end location. Not achievable over all paths.