Group 8 special parameters – Delta Electronics AC Motor Drive VFD-G User Manual
Page 65

Chapter 4 Parameters|
4-14
Revision July 2008, EG03, SW V1.06
Parameter
Functions
Settings
Factory
Setting
Customer
07-08 Calculate
Total
Running Time of the
Motor (Min)
00 to 1439 Min
00
07-09 Calculate
Total
Running Time of the
Motor (Day)
00 to 65535 Day
00
07-10
Electric Bill for One
Time
Read Only
Read
07-11 Accumulated
Electric
Bill (per currency unit)
Read Only
Read
07-12 Accumulated
Electric
Bill (per 10
4
currency
unit)
Read Only
Read
07-13
Electric Rate (per
currency unit)
0.01 to 655.35
0.6
Group 8 Special Parameters
Parameter
Functions
Settings
Factory
Setting
Customer
08-00
DC Braking Current
Level
00~100% 00
08-01
DC Braking Time
during Start-up
0.0~60.0 Sec
0.0
08-02
DC Braking Time
during Stopping
0.00~60.00 Hz
0.0
08-03 Start-point
for
DC
Braking
0.00~160.00 Hz
0.00
08-04 Momentary
Power
Loss Operation
Selection
00: Disable
01: Trace from top downward
02: Trace from bottom upward
00
08-05 Maximum
Allowable
Power Loss Time
0.1~5.0 Sec
2.0
08-06
Speed Search Time
0.1~5.0 Sec
0.5
08-07 Maximum
Speed
Search Current
30~150% 110
08-08 BB
speed
search
method
00: Trace from top downward
01: Trace from bottom upward
00
08-09
Auto Restart Times
after Fault
00~10 00
08-10
Auto Restart Time after
Fault
00 to 60000 sec
600