Chapter 4 Parameters|

4-76

Revision July 2008, EG03, SW V1.06

RTU mode:

Command message:

Response message:

Error response message

ADR 01H

ADR 01H

ADR 01H

CMD

06H

CMD 1

06H

CMD 1

86H

data 01H

data 01H

Error

code

02

Starting address

00H

Starting address

00H

CRC CHK LOW

C3H

data

17H

data

17H

CRC CHK HIGH

A1H

00H

70H

CRC CHK LOW

87H

CRC CHK LOW

87H

CRC CHK HIGH C6H

CRC CHK HIGH

C6H

Command code: 08H, loop detection

This command is used to test the communication condition between master control

equipment (usually is PC or PLC) and AC drive. AC drive will deliver the data that received

from AC drive to master control equipment.

For example:

ASCII mode:

Command message:

Response message:

Error response message

STX ‘:’

STX ‘:’

STX ‘:’

ADR 1

‘0’

ADR 1

‘0’

ADR 1

‘0’

ADR 0

‘1’

ADR 0

‘1’

ADR 0

‘1’

CMD 1

‘0’

CMD 1

‘0’

CMD 1

‘8’

CMD 0

‘8’

CMD 0

‘8’

CMD 0

‘8’

data ‘0’

data ‘0’

Error ‘0’

Starting ‘0’

Starting ‘0’

code ‘2’

address

‘0’

‘0’

LRC CHK 0

‘6’

‘0’

‘0’

LRC CHK 1

‘D’

data ‘1’

data ‘1’

END

1 CR

‘7’

‘7’

END

0

LF

‘7’

‘7’

‘0’

‘0’

LRC CHK 1

‘7’

LRC CHK 1

‘7’

LRC CHK 0

‘0’

LRC CHK 0

‘0’

END 1

CR

END 1

CR

END 0

LF

END 0

LF