2.2 External Wiring

Motor

Output AC

Line Reactor

Power Supply

Magnetic

contactor

Input AC

Line Reactor

EMI Filter

R/L1

S/L2

T/L3

U/T1

V/T2

W/T3

+2

Zero-phase

Reactor

Zero-phase

Reactor

FUSE/NFB

-

BR

VF

D

B

B

rak

e

re

s

ist

o

r

B

rak

e

un

it

DC

Choke

+1

Items Explanations

Power
supply

Please follow the specific power
supply requirements shown in
Appendix A.

Fuse/NFB
(Optional)

There may be an inrush current during
power up. Please check the chart of
Appendix B and select the correct fuse
with rated current. Use of an NFB is
optional.

Magnetic
contactor
(Optional)

Please do not use a Magnetic
contactor as the I/O switch of the AC
motor drive, as it will reduce the
operating life cycle of the AC drive.

Input AC
Line Reactor
(Optional)

Used to improve the input power
factor, to reduce harmonics and
provide protection from AC line
disturbances (surges, switching
spikes, short interruptions, etc.). AC
line reactor should be installed when
the power supply capacity is ≧500kVA
or phase lead reactor will be switched.
And the mains wiring distance

10m.

Please refer to Appendix B for more
details.

Zero-phase
Reactor
(Ferrite Core
Common
Choke)
(Optional)

Zero phase reactors are used to
reduce radio noise especially when
audio equipment is installed near the
inverter. Effective for noise reduction
on both the input and output sides.
Attenuation quality is good for a wide
range from AM band to 10MHz.
Appendix B specifies the zero phase
reactor. (RF220X00A)

EMI filter
(Optional)

To reduce electromagnetic
interference, please refer to Appendix
B for more details.

Brake
Resistor
(Optional)

Used to reduce the deceleration time
of the motor. Please refer to the chart
in Appendix B for specific Brake
Resistors.

Output AC
Line Reactor
(Optional)

Motor surge voltage amplitude
depends on motor cable length. For
applications with long motor cable
(>20m), it is necessary to install a
reactor at the inverter output side.