5.10 Motor Speed cannot be Changed

Motor can run but
cannot change speed

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Check if the setting of the
max. frequency is too low

Check to see if frequency is
out of range (upper/lower)

boundaries

Modify the setting

Modify the setting

Yes

No

Yes

If the setting of

Pr.05-17toPr.05-31
is too high

Yes

If finished with
executing
Pr.05-15

If the setting of
Pr.05-00 to Pr.05-14

are the same

Is it in PLC mode

Press UP/DOWN key

to see if speed has
any change

If there is any change
of the signal that sets

frequency (0~10V and
0~1A)

Check if the wiring between

MI1~MI4 to DCM is correct

Correct

wiring

Check if frequency for

each step is different

Check if the wiring of
external terminal is correct

Change frequencysetting

Check if accel./decel.

time is set correctly

Please set suitable

accel./decel. time by
load inertia

Maybe AC motor drive has malfunction or misoperation

due to noise. Please contact DELTA.

Change defective

potentiometer