whether to delete the dynamic network variable.
Scope: All networks, current IzoT Commissioning Tool computer
Delete Dynamic NV
when NV SmartShape
is Deleted
Deletes a dynamic network variable from a device when its network
variable SmartShape is deleted from a functional block SmartShape.
You have three choices:
• No. The dynamic network variable is not deleted.
• Yes. The dynamic network variable is automatically deleted.
• Ask. IzoT Commissioning Tool will prompt you to decide
whether to delete the dynamic network variable. This is the
default.
Scope: All networks, current IzoT Commissioning Tool computer
Reference Shape
Alignment
Select how IzoT Commissioning Tool aligns reference connection
SmartShapes. The alignment settings are applied if the Align
Reference Shapes option is set on the functional block. To set this
option, right-click a functional block, point to Display Options, and
click Align Reference Shapes if it is not already set.
Horizontal Alignment
Selects how IzoT Commissioning Tool aligns overlapping connector
reference SmartShapes. You have three choices:
• Staggered Wide. Connector reference SmartShapes are
staggered horizontally, in two columns, with their centers
aligned. This is the default.
• Staggered Narrow. Connector reference SmartShapes are
staggered horizontally, in two columns, with the outermost
reference SmartShapes located close to the functional block
SmartShape and somewhat overlapping with reference
SmartShapes above and below them.
• Overlapped. Connector reference SmartShapes are not
staggered and will overlap.
Scope: Current network, current IzoT Commissioning Tool
computer
Overlap Threshold
Factor
Determines the point at which IzoT Commissioning Tool will
overlap multiple connector reference SmartShapes that are attached
to the same network variable SmartShape on one side of a functional
block. Overlapping connector reference SmartShapes cannot be
aligned with the network variable SmartShapes to which they are
connected.
If the overlap threshold factor multiplied by the height of the
functional block SmartShape is greater than the total height of the
reference connector SmartShapes (including spacing), the reference
connector SmartShapes will not be overlapped.
The default overlap threshold factor is 1.3. For the best appearance,
keep this value below 2.
Scope: Current network, current IzoT Commissioning Tool
computer
Ref SmartShape
Spacing Factor
Determines the vertical spacing between multiple connector
reference SmartShapes when they are not aligned with the network
330