3 calculation function, Calculation value (calc value), 3 calculation function -42 – KEYENCE IL Series User Manual
Page 96: Calculation value (calc value) -42, Calculation function -42, Calculation function
4-42
IL-E
4
Setting V
ar
iou
s F
unct
ions
4-3
Calculation Function
The internal measurement value (R.V.) for the "main unit" and the "expansion unit
additionally installed next to the main unit (referred to as expansion unit 1)" can be
calculated (addition or subtraction).
If there is more than one expansion unit, the calculation function can be used between the
"main unit" and the "expansion unit 1" only.
There are two calculation modes for the calculation function.
• Addition Mode
• Subtraction Mode
The calculation result of the internal measurement value (R.V.) for the "main unit" and the
"expansion unit 1" is referred to as calculation value (CALC value).
The "main unit" operates with the calculation value (CALC value) considered as a judgment
value (P.V.).
The "expansion unit 1" operates with its internal measurement value (R.V.) considered as a
judgment value (P.V.).
The calculation function cannot be used when a mixture of units from the following groups
is used: IL-S025/IL-030/IL-S065/IL-065/IL-100, IL-300/IL-600, and IL-2000.
The calculation function can be used when a combination of units from within each of the
following groups is used: IL-S025/IL-030/IL-S065/IL-065/IL-100 and IL-300/IL-600. The
calculation function can also be used when multiple IL-2000s are used in combination.
Point
1. When using the calculation function, the setting of the averaging
of expansion unit and sampling rate will be changed to the same
setting as the main unit.
2. If the sampling rate is set to 0.33 ms or if the interference
prevention function is ON, the timing for updating the main unit
and expansion unit's internal data will not match. In this case,
when measuring a moving target using the calculation function,
the measured value may be greatly differ from the actual value.
Calculation Value (CALC value)
Reference
• The calculation value (CALC value) can be displayed on the sub display
(lower level) on the main unit.
"Sub Display (Lower Level)" (page 3-4)
• When the hold function is used, the calculation value (CALC value) is not
held.