beautypg.com

KEYENCE IL Series User Manual

Page 85

background image

4-2 Basic Settings and Advanced Settings

4-31

IL-E

4

Setting V

ar

iou

s F
unct

ions

Zero shift input

When the zero shift input is set to ON, the internal measurement value (R.V.) is shifted
(offset) to an arbitrary shift target value.

“3-5 Zero Shift Function (Shifting the Internal Measurement Value (R.V.))” (page 3-18)

„

Timing chart

„

Minimum Input Time

ON time: 20 ms
OFF time: 20 ms

Reset input

When the reset input is turned ON while using the hold function, the judgment value (P.V.)
in the held state is canceled and the value becomes [-----].

"6. Hold Function" (page 4-15)

„

Timing chart

„

Minimum Input Time

ON time: 20 ms
OFF time: 20 ms

Internal measurement
value (R.V.)

Max. 20 ms

Min. 20 ms

Min. 20 ms

R.V. before shifted

R.V. after shifted

ON

OFF

Zero shift input

Judgment value
(P.V.) judgment
output

Max. 20 ms

Min. 20 ms

Min. 20 ms

Before resetting

[- - - - - ]

ON

OFF

Reset input