2-2 Connecting and Mounting the Sensor Head

2-11

IL-E

2

Installation and C

onnection

Attaching the sensor head cable connector (OP-84338: optional accessory)

Cut the sensor head connection cable to the required length and attach the new connector
to use the sensor. The attaching method is the same for both transmitter and receiver.

1

Cut the cable to the required length and strip approx. 15 mm of insulation
from the end of the cable.

2

Insert each cable to the end matching to the same color marks on the
connector.

The cables should be inserted to the end and held in place.

3

Confirm that all cables are inserted to the specified position and crimp
them using pliers or a similar tool.

Point

Do not strip the core wire insulation.

Point

If the connector is changed, make sure to connect it to the
amplifier and confirm the normal operation.
If it does not operate normally, crimp the connector again with
pliers.
Once the connector is crimped, it cannot be reused.

Blue

White

Black

Brown

Insert further