Laser emission stop input

The laser emission remains interrupted while the laser emission stop input is ON. The laser
emission indicator on the sensor amplifier lights off while the laser emission is stopped.

"Amplifier control unit" (page 1-6)

„

Timing chart

„

Minimum Input Time

ON time: 2 ms
OFF time: 2 ms

Set whether to switch the bank with the amplifier buttons or with external inputs.

* If switching with buttons is selected, the bank can be switched only with the buttons.

If switching with external input is selected, the bank can be switched only from the
external input cable.

Reference

Measurements are disabled while the laser emission is stopped. R.V. is
determined by the alarm process.

“2 Display Screen and Output” (page A-8)

Max. 20 ms

Max. 20 ms

Min. 20 ms

ON

OFF

Laser emission

stop input

Laser being transmitted

Laser being transmitted

Laser emission being stopped

12. Bank Switching Method

DP-

Setting

Description

Default

value

Switching with buttons

The banks are switched by operating the amplifier buttons.

c

Switching with external
input

The banks are switched only by turning ON/OFF the bank
A input or bank B input set in "11. External input".