KEYENCE IL Series User Manual
Page 72
4-2 Basic Settings and Advanced Settings
4-18
4
Setting V
ar
iou
s F
unct
ions
IL-E
Bottom hold
The minimum value of the specified period (sampling period) is held as a judgment value (P.V.).
When "Level" is set for "7. Timing Input" (page 4-23)
The sampling period is from the falling edge of the timing input to the next rising edge. On the
rising edge, the internal measurement value (R.V.) minimized during the sampling period is held
as a judgment value. When the timing input is turned OFF, the next sampling period begins.
*1
"11. External Input" (page 4-30)
*2 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the
calculation function is used.
“4-3 Calculation Function” (page 4-42)
*3 If the R.V. value (or CALC value) causes an alarm even once during the sampling period, the
hold results will be "-----".
When "Edge" is set for "7. Timing Input" (page 4-23)
The sampling period is from the rising edge of the timing input to the next rising edge of the
timing input. On the rising edge, the internal measurement value (R.V.) minimized during
the sampling period is held as a judgment value. When the timing input is turned ON, the
next sampling period has already begun.
Display value
Time
Timing Input
Sampling period
Sampling period
Sampling period
ON
OFF
Power ON or
Reset input *
1
After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.
Judgment value (P.V.)
Internal measurement value (R.V.)*
2
Display value
Time
Timing Input
Sampling period
Sampling period
Sampling period
ON
OFF
Power ON or
Reset input *
1
After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.
Judgment value (P.V.)
Internal measurement value (R.V.)*
2