4-2 Basic Settings and Advanced Settings

4-39

IL-E

4

Setting V

ar

iou

s F
unct

ions

* When the mutual-interference prevention function is ON, the expansion unit's sampling

rate and number of average times are the same as the main unit settings.

The number of digits of the judgment value (P.V.), the internal measurement value (R.V.) or
the calculation value (CALC value) displayed on the sensor amplifier is set.

*1 The 7 segment inscription of [dEFLt] is IL-S025/IL-030/IL-S065/IL-065/IL-100: 0.01, IL-300/

IL-600: 0.1, and IL-2000: 1.

*2 This cannot be set under IL-300/IL-600/IL-2000.

*3 This cannot be set under IL-2000.

Point

• If the data between the heads is not synchronized when using the calcu-

lation function or when the DL series is connected, disable the

mutual-interference prevention function and set the main unit's sam-

pling rate to a rate other than 0.33 ms. When the mutual-interference pre-

vention function is enabled, or 0.33 ms is set, the timing for updating the

main unit and expansion unit's internal data will not match. In this case,

when measuring a moving target using the calculation function, the

measured value may greatly differ from the actual value.

• The timing cannot be synchronized for the following time after the

power has been turned ON and after the interference prevention set-

ting has been changed.
When sampling rate is 0.33 ms/1 ms/2 ms : 3 seconds
When sampling rate is 5 ms

: 15 seconds

“4-3 Calculation Function” (page 4-42)

• The screen is skipped if the sampling rate is set to 2 ms or 5 ms for

IL-S025/IL-030/IL-S065/IL-065/IL-100, and dEFLt, 2 ms or 5 is set for

IL-300/IL-600/IL-2000.

• Skipped if there is no expansion unit or if expansion unit 1 is not

an IL Series unit.

• For those items with even one amplifier included and shipped

before December 21th, 2010, when the “3.AVE” settings of the
main unit are [
diFF]/[HPF], the screen will be skipped.

Interference

prevention

Description

Default

value

OFF

Interference prevention function OFF

c

ON

Interference prevention function ON

15. Display Digit

F52

Display Digit

Description

Default value

dEFLt

A different value is displayed for each head.

*1

c

0.001

3 decimal places

*2 *3

0.01

Truncate the 3rd decimal place

*3

0.1

Truncate the 2nd decimal place

1

Truncate the 1st decimal place