Auto peak hold
When the internal measurement value (R.V.) goes beyond the specified trigger level, the
sampling begins. When it falls below the trigger level, the sampling finishes. When the
sampling finishes, the maximum internal measurement value (R.V.) during the sampling
period is held as a judgment value (P.V.).
The external input is not required.
*1
"11. External Input" (page 4-30)
*2 After the power is turned on or reset is input, the judgment value (P.V.) is [-----] until the
judgment value (P.V.) is first held.
*3 While the timing input is ON, the sampling does not start. If the sampling is already in
process, it continues.
*4 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the
calculation function is used.
“4-3 Calculation Function” (page 4-42)
Trigger level setting screen
When the auto peak hold is set, the display goes to the trigger level setting screen.
Press S / T button on the trigger level setting screen to specify the trigger level.
IL-S025/IL-030/IL-S065/IL-065/IL-100
IL-300/IL-600
IL-2000
Reference
• The operation by the timing input is the same regardless of the "7. Timing
• After the sampling starts, if the internal measurement value (R.V.)
becomes "-----" before the sampling falls below the specified trigger
level, the sampling is automatically finished and the maximized value
during the sampling period is held as a judgment value (P.V.).
Display value
Time
Timing Input
Trigger level
Hysteresis
ON
OFF
Power ON or
Reset input *
1
*
3
*
2
Judgment value (P.V.)
Internal measurement value (R.V.)*
4
Item
Setting range
Default value
Trigger level
-99.999 to 99.999
1.000
Item
Setting range
Default value
Trigger level
-999.99 to 999.99
10.00
Item
Setting range
Default value
Trigger level
-9999.9 to 9999.9
100.0
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
VT)
HOLD CALC CHECK
#WVQ2
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
*.&
GO
HOLD
CALC
CHECK
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
&.;
GO
HOLD
CALC
CHECK
6. Hold function
Trigger level setting screen
8. Delay timer
[MODE]
or X
[MODE]
or X