KEYENCE IL Series User Manual
Page 37
3-2 Operations on the Main Screens
3-5
IL-E
3
Basic Oper
ations
(1) R.V. display screen
The internal measurement value (R.V.) is displayed. The displayed value is not held.
(2) Analog output screen (Displayed when using main unit's analog output)
The voltage value (unit: V) or current value (unit: mA) of the analog output is displayed.
"3-1 Operation When the Power is Turned on for the First Time" (page 3-2)
"3-3 Initial Reset (Initialize)" (page 3-8)
(3) HIGH side setting value screen
The upper limit of the acceptable range (tolerance setting value) for the object is
displayed. Also, the setting value can be changed. If the judgment value (P.V.) exceeds
the value set here, the HIGH judgment output turns on.
"3-4 Setting the Tolerance Setting Value" (page 3-10)
(4) LOW side setting value screen
The lower limit of the acceptable range (tolerance setting value) for the object is
displayed. Also, the setting value can be changed. If the judgment value (P.V.) falls
below the value set here, the LOW judgment output turns on.
"3-4 Setting the Tolerance Setting Value" (page 3-10)
(5) Shift target value screen
When the zero shift button is pressed or the zero shift input is set to ON, the internal
measurement value (R.V.) is adjusted to the value set here.
"3-5 Zero Shift Function (Shifting the Internal Measurement Value (R.V.))" (page 3-18)
(page 3-18)
(6) Calculation value screen (Displayed when using main unit's calculation function)
The calculated value (CALC value) is displayed. The displayed value is not held.
"4-3 Calculation Function" (page 4-42) (page 4-39)