background image

4-4 Calibration Function

4-46

4

Setting V

ar

iou

s F
unct

ions

IL-E

[SEt1]

3

Insert workpiece A for which the measured value is
known, and using the
S / T buttons, set the "R.V. you
wish to display (1)" for that workpiece A.

The current internal measurement value is displayed on the
main display (upper level). [SEt1] and the "R.V. you wish to
display (1)" are alternately displayed on the sub display (lower
level).
IL-S025/IL-030/IL-S065/IL-065/IL-100

IL-300/IL-600

IL-2000

4

Press the [SET] button. (SET1 confirmation operation)

After [SEt1] blinks several times on the sub display (lower
level), [SET2] is displayed.

[SET] button

[SEt2]

5

Insert workpiece B for which the measured value is
known, and using the
S / T buttons, set the "R.V. you
wish to display (2)" for that workpiece B.

The current internal measurement value is displayed on the
main display (upper level). [SEt2] and the "R.V. you wish to
display (2)" are alternately displayed on the sub display (lower
level).
IL-S025/IL-030/IL-S065/IL-065/IL-100

IL-300/IL-600

IL-2000

[SET] button

LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

HOLD

CALC

CHECK

R.V. value

Setting you wish to display

Item

Setting range

Default value

set1

-99.999 to 99.999

0.000

Item

Setting range

Default value

set1

-999.99 to 999.99

0.00

Item

Setting range

Default value

set1

-9999.9 to 9999.9

0.0

LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI SHIFT

ZERO SHIFT

TIMING

LO

HOLD CALC CHECK

Item

Setting range

Default value

set2

-99.999 to 99.999

5.000

Item

Setting range

Default value

set2

-999.99 to 999.99

50.00

Item

Setting range

Default value

set2

-9999.9 to 9999.9

500.0