15 show track – CANOGA PERKINS 9171 Command Reference User Manual
Page 329

CanogaOS Command Reference
18-10
Command Syntax
delay down seconds
no delay down
Syntax Description
seconds
Time range is from 1 to 180.
Command Mode
Track mode
Defaults
Default value is 0 seconds.
Examples
In the following example, the delay down command is used to configure delay when object state
is turned from up to down:
Switch(config)#track 1
Switch(config-track)#delay down 30
Related Commands
Show track
18.15 SHOW TRACK
To show TRACK entries, use show track in EXEC mode.
Command Syntax
show track (objectid)
Syntax Description
objectid
Object identity is used to identify track object, its
range is from 1 to 500;
Command Mode
Exec mode
Defaults
none
Examples
In the following example, the show track command is used to show track entries:
Switch#show track
Track 2