beautypg.com

Dell PowerEdge C6220 User Manual

Page 123

background image

Using the System Setup Program | 123


Token

Setup option

Description

02C7

Data Reuse
Optimization

Sets to enable (Default) for HPC applications.

02C8

Data Reuse
Optimization

Sets to disable for energy efficiency.

02C9

QPI Bandwidth
Priority

Sets to Compute (Default) for computation-intensive
applications.

02CA

QPI Bandwidth
Priority

Sets to I/O for I/O-intensive applications.

02CE

DCU IP

Prefetcher

This field enables (Default) the DCU IP Prefetcher.

02CF

DCU IP
Prefetcher

This field disables the DCU IP Prefetcher.

401A

Terminal Type

The BIOS console redirection, if enabled, operates in

VT100 emulation model. See also tokens BFh, C0h, and

D7h.

401B

Terminal Type

The BIOS console redirection, if enabled, operates in

ANSI emulation model. See also tokens BFh, C0h, and

D7h.

401C

Redirection After
BIOS POST

The BIOS console redirection, if enabled, continues to
operate after the OS boot hand-off.


401D

Redirection After
BIOS POST

The BIOS console redirection, if enabled, operates
during the BIOS boot only and is disabled prior to OS
boot hand-off. See also tokens BFh, C0h, D7h, 401Ah
and 401Bh.

4022

1st Boot Device Whenever the BIOS boots the system, the first PXE-

capable device is inserted as the first device in the boot

sequence. Enabling this feature causes the BIOS operation

to occur on the next and all subsequent boots and causes a

change in the system's defined boot sequence. The BIOS

chooses the first PXE-capable device as the system's

onboard network controller, if present and enabled, or the

first bootable network device found in the system's

standard PCI search order.
whichever comes first.