Dell PowerEdge C6220 User Manual
Page 291
Installing System Components | 291
3 Replace the screw that secure the sensor board to the hard drive cage.
4 Connect the sensor board cable to the sensor board. See Figure 3-99.
5 Replace the hard drive cage into the chassis. See Figure 3-84.
6 Replace the screws that secure the hard-drive cage to the chassis. See
7 Connect all the cables to the backplane. See Figure 3-82 for 2.5-inch
hard drives.
You must route these cables properly on the chassis to prevent them
from being pinched or crimped.
8 Connect front panel cables to the power distribution board. See Figure
3-96 or Figure 3-99.
You must route these cables properly on the chassis to prevent them
from being pinched or crimped.
9 Close the system. See “Closing the System” on page 234.
10 Replace the hard drives. See “Installing a Hard Drive into a Hard-Drive
11 Reconnect the system to its electrical outlet and turn on the system,
including any attached peripherals.
Cable Routing for Sensor Board and Front Panel for 2.5” Hard Drive
System
1 Connect the Y-shaped cable for sensor board and front panel 2 to the
connector on the power distribution board 1, and connect the other
two ends of the cable to the connectors on the sensor board and the
front panel 2 respectively.
2 Connect the front panel cable to the connector on the power
distribution board 1, and connect the other end of the cable to the
connector on the front panel 1.