beautypg.com

Dell PowerEdge C6220 User Manual

Page 67

background image

Using the System Setup Program | 67


3 Enter Set BMC LAN Configuration screen and verify the following

settings:

Remote Access: enabled

Serial port number: COM2 as SOL

Serial Port Mode: 115200 8,n,1

Flow Control: None

Redirection After BIOS POST: Always

Terminal Type: VT100

To do this, see “Remote Access Configuration” on page 109. Note that the
host and client need to have the same network section.

BMC Serial Over LAN
There are two modes of BMC LAN port configuration-Dedicated NIC and
Shared NIC to enable Serial Over LAN (SOL) feature. The following steps
show setup process about the LAN connection and BIOS setup settings for
Dedicated-NIC and Shared-NIC.

To enable SOL feature in the mode of Dedicated-NIC, please perform the
following steps:

1 Connect the LAN cable to management port. For location of

management port on the back panel, see Figure 1-18 item 7.

2 Enter the server BIOS setup screen.
3 Enter Set BMC LAN Configuration screen and verify the following

settings:

Remote Access: enabled

Serial port number: COM2 as SOL

Serial Port Mode: 115200 8, n, 1

Flow Control: None

Redirection After BIOS POST: Always

Terminal Type: VT100

To do this, see “Remote Access Configuration” on page 109. Note that the
last four options need to sync with the host and client.
4 Enter LAN Configuration screen and verify the following settings: