Direct backplane jumper settings – Dell PowerEdge C6220 User Manual

Page 323

background image

Jumpers and Connector | 323


NOTE: The * in the table of system configuration jumper describes the default
status and the default state is not active state.

Direct Backplane Jumper Settings

CAUTION: Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.

The function of jumpers installed on 3.5" HDD Direct Backplane and 2.5"
HDD Direct Backplane is the same. Following is an example using the
jumpers installed on 3.5" HDD Direct Backplane.

Figure 5-18. Jumper Installed on Direct Backplane

Table 5-2. Jumpers Installed on Direct Backplane
Jumper

Function

Off

On

SW1 (pin1-2)

Reserved

*Disable

Enable

SW2 (pin3-4)

Reserved

*Disable

Enable

SW3 (pin5-6)

SGPIO I

2

C Select

*Disable

Enable

SW4 (pin7-8)

MFG Test

*Disable

Enable

NOTE: The * in the table of Direct Backplane jumper describes the default status
and the default state is not active state.