Dell PowerEdge C6220 User Manual
Page 118

118
|
Using the System Setup Program
Token
Setup option
Description
0169
Max CPUID
Value Limit
Some OS's (NT4) will fail if the value returned in EAX
is > 3 when CPUID instruction is executed with EAX=0.
This setting will limit CPUID function to 3.
016F
Embedded SAS
Controller
Disables the SAS controller. The token applies to on-board
SAS controller
0170
Embedded SAS
Controller
Enables the SAS controller. Sets the device class code as
AHCI/RAID and executes the RAID Option ROM. This
token applies to on-board SAS controller.
0171
Adjacent Cache
Line Prefetch
The processor will only fetch the cache line that contains
the data currently required by the processor.
0172
Adjacent Cache
Line Prefetch
Enables the processor to fetch the adjacent cache line in
the other half of the sector.
0173
Hardware
Prefetcher
Disables the processor's HW prefetcher.
0174
Hardware
Prefetcher
Enables the processor' HW prefetcher.
0178
Remote Access
Enables Serial Console Redirection.
0189
External USB
PORT2
This feature will allow the users to electrically disable the
external USB port2.
018A
External USB
PORT2
This feature will allow the users to electrically enable the
external USB port2.
0199
Power Saving
Features
This feature will allow users to disable the feature that
allows SATA HDDs to initiate link power management
transitions.
019A
Power Saving
Features
This feature will allow users to enable the feature that
allows SATA HDDs to initiate link power management
transitions.
01C4
NUMA Support For BIOS Setup to allow user enable the node interleave
option. This is for NUMA systems that allow memory
interleaving across all processor nodes.
01C5
NUMA Support For BIOS Setup to allow user disable the node interleave
option. This is for NUMA systems that allow memory
interleaving across all processor nodes.